Paper-Based Biosensor for the Detection of Sepsis Using MMP-9 Biomarker in FIP Mice Model

GND
1324187441
ORCID
0000-0001-8045-9839
Zugehörigkeit
Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, AlTakhassusi Rd, Riyadh 11533, Saudi Arabia;
Alekhmimi, Nuha Khalid;
ORCID
0000-0001-7102-629X
Zugehörigkeit
Cell Therapy and Immunobiology Department, King Faisal Specialist Hospital and Research Center, Riyadh 13541, Saudi Arabia;
Raddadi, Zeyad;
Zugehörigkeit
Saudi Food and Drug Authority, Riyadh 13513, Saudi Arabia;
Alabdulwahed, Abdulelah A.;
ORCID
0000-0002-5558-0060
Zugehörigkeit
Department of Chemistry, Khalifa University of Science and Technology, Abu Dhabi P.O. Box 127788, United Arab Emirates;
Eissa, Shimaa;
GND
143008919
Zugehörigkeit
Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University, 07745 Jena, Germany;(D.C.-M.);(J.P.)
Cialla-May, Dana;
GND
131701819
Zugehörigkeit
Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University, 07745 Jena, Germany;(D.C.-M.);(J.P.)
Popp, Jürgen;
ORCID
0000-0002-1372-9883
Zugehörigkeit
College of Medicine, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Rd, Riyadh 11533, Saudi Arabia;
Al-Kattan, Khaled;
ORCID
0000-0003-2187-1430
Zugehörigkeit
Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, AlTakhassusi Rd, Riyadh 11533, Saudi Arabia;
Zourob, Mohammed

Sepsis is an immune response to a microbial invasion that causes organ injury and dysfunction due to a systemic inflammatory response. Sepsis is a serious, life-threatening condition and a widely recognized global health challenge. Given its high death rate, it is critical to diagnose sepsis and start treatment as early as possible. There is an urgent need for a sensitive and rapid screening method for detecting sepsis. In this study, we investigated the use of MMP-9 as a biomarker for sepsis. A colorimetric paper-based biosensor was used for the detection of MMP-9 utilizing peptide-magnetic nanoparticle conjugates. The method is based on the cleavage of the MMP-9-specific peptide by the protease leading to the detaching of the magnetic beads from the sensor surface and changing of color. A fecal intraperitoneal (FIP) challenge was used to induce sepsis in mice, and an MMP-9 secretion was measured by taking blood and Bronchoalveolar Lavage (BAL) fluid samples at 1 h, 2 h, 4 h, and 20 h (early sepsis) post-challenge intervals. The results of the paper-based sensor for the detection of MMP-9 levels in blood samples and BAL samples were compared with ELISA and Western Blot. We found that both blood and BAL levels of MMP-9 increased immediately and could be detected as early as 1 h in FIP mice post-challenge. Our work adds evidence to the assertion that MMP-9 is a reliable biomarker for the detection of sepsis at early stages.

Zitieren

Zitierform:
Zitierform konnte nicht geladen werden.

Rechte

Rechteinhaber: © 2023 by the authors.

Nutzung und Vervielfältigung: