A Comparative Analysis of Morphology and Dimensions of Functional Blebs following PRESERFLO-Microshunt and XEN-Gel-Stent, a Study Using Anterior Segment OCT

GND
1211562948
ORCID
0000-0003-2478-7007
Zugehörigkeit
Department of Ophthalmology, Jena University Hospital, 07747 Jena, Germany
Hasan, Somar M.;
GND
1272284352
Zugehörigkeit
Department of Ophthalmology, Jena University Hospital, 07747 Jena, Germany
Theilig, Theresa;
GND
132839347X
Zugehörigkeit
Department of Ophthalmology, Jena University Hospital, 07747 Jena, Germany
Papadimitriou, Menelaos;
GND
172832470
Zugehörigkeit
Department of Ophthalmology, Jena University Hospital, 07747 Jena, Germany
Meller, Daniel

Evaluation of bleb morphology is a vital part of successful filtration glaucoma surgery. The PRESERFLO-MicroShunt (PRESERFLO) and XEN-Gel-Stent (XEN) are drainage devices implanted using different surgical approaches (ab externo and ab interno, respectively), potentially resulting in distinct bleb morphology. Understanding these morphological differences is essential for postoperative care. In this study, we retrospectively examined functioning blebs following PRESERFLO and XEN implantation using high-resolution anterior segment OCT imaging. Qualitative assessment utilizing the Jenaer Bleb Grading System and quantitative assessment measuring 12 parameters representing bleb dimensions were conducted, and the results were compared between the two groups. A total of 80 eyes from 80 patients were included (41 after PRESERFLO, 39 after XEN). Functioning blebs following PRESERFLO exhibited a higher frequency of hyperreflective tenon changes compared to XEN (31.7% vs. 10.3%, respectively, p = 0.02) and a lower frequency of cavernous changes (17.1% vs. 35.9%, p = 0.05). Additionally, PRESERFLO blebs showed a higher frequency of visible episcleral lakes (92.7% vs. 30.8%, p < 0.001). Furthermore, PRESERFLO blebs demonstrated larger height (2.13 ± 0.5 vs. 1.85 ± 0.6 mm, p = 0.03), width (10.31 ± 2.3 vs. 9.1 ± 2.3 mm, p = 0.02), length (9.13 ± 1.8 vs. 8.24 ± 1.9 mm, p = 0.04), posterior location relative to the limbus (6.21 ± 1.2 vs. 5.21 ± 1.8 mm, p = 0.005), and a thicker bleb wall (1.60 ± 0.5 vs. 1.1 ± 0.4 mm, p = 0.004). Functioning blebs following PRESERFLO and XEN displayed morphological distinctions, likely attributed to variations in surgical techniques (ab externo vs. ab interno) and stent dimensions. These morphological differences should be taken into consideration when evaluating blebs, as they could impact assessments of bleb functionality and influence decisions regarding postoperative interventions.

Zitieren

Zitierform:
Zitierform konnte nicht geladen werden.

Rechte

Rechteinhaber: © 2023 by the authors.

Nutzung und Vervielfältigung: