A GPS-referenced wavelength standard for high-precision displacement interferometry at λ = 633 nm

ORCID
0000-0003-1398-8989
Zugehörigkeit
Institute of Process Measurement and Sensor Technology, Technische Universität Ilmenau, 98693 Ilmenau, Germany
Blumröder, Ulrike;
Zugehörigkeit
Precision Engineering Division, Physikalisch Technische Bundesanstalt (PTB), 38116 Braunschweig, Germany
Köchert, Paul;
ORCID
0000-0002-6060-7248
Zugehörigkeit
Institute of Process Measurement and Sensor Technology, Technische Universität Ilmenau, 98693 Ilmenau, Germany
Fröhlich, Thomas;
ORCID
0000-0003-1832-7143
Zugehörigkeit
Institute of Process Measurement and Sensor Technology, Technische Universität Ilmenau, 98693 Ilmenau, Germany
Kissinger, Thomas;
ORCID
0000-0002-5611-7852
Zugehörigkeit
Institute of Process Measurement and Sensor Technology, Technische Universität Ilmenau, 98693 Ilmenau, Germany
Ortlepp, Ingo;
Zugehörigkeit
Precision Engineering Division, Physikalisch Technische Bundesanstalt (PTB), 38116 Braunschweig, Germany
Flügge, Jens;
ORCID
0000-0002-3137-924X
Zugehörigkeit
Precision Engineering Division, Physikalisch Technische Bundesanstalt (PTB), 38116 Braunschweig, Germany
Bosse, Harald;
ORCID
0000-0002-1672-2978
Zugehörigkeit
Institute of Process Measurement and Sensor Technology, Technische Universität Ilmenau, 98693 Ilmenau, Germany
Manske, Eberhard

Since the turn of the millennium, the development and commercial availability of optical frequency combs has led to a steadily increase of worldwide installed frequency combs and a growing interest in using them for industrial-related metrology applications. Especially, GPS-referenced frequency combs often serve as a "self-calibrating" length standard for laser wavelength calibration in many national metrology institutes with uncertainties better than u = 1 × 10^-11. In this contribution, the application of a He-Ne laser source permanently disciplined to a GPS-referenced frequency comb for the interferometric measurements in a nanopositioning machine with a measuring volume of 200 mm × 200 mm × 25 mm (NPMM-200) is discussed. For this purpose, the frequency stability of the GPS-referenced comb is characterized by heterodyning with a diode laser referenced to an ultrastable cavity. Based on this comparison, an uncertainty of u = 9.2 × 10^-12 (τ = 8 s, k = 2) for the GPS-referenced comb has been obtained. By stabilizing a tunable He-Ne source to a single comb line, the long-term frequency stability of the comb is transferred onto our gas lasers increasing their long-term stability by three orders of magnitude. Second, short-term fluctuations-related length measurement errors were reduced to a value that falls below the nominal resolving capabilities of our interferometers (ΔL/L = 2.9 × 10^-11). Both measures make the influence of frequency distortions on the interferometric length measurement within the NPMM-200 negligible. Furthermore, this approach establishes a permanent link of interferometric length measurements to an atomic clock.

Zitieren

Zitierform:
Zitierform konnte nicht geladen werden.

Rechte

Nutzung und Vervielfältigung: