Me-doped Ti-Me intermetallic thin films used for dry biopotential electrodes: a comparative case study

ORCID
0000-0002-8266-0111
Zugehörigkeit
1 Centro de Física das Universidades do Minho e Porto, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal; marcopsr@gmail.com (M.S.R.); joelborges@fisica.uminho.pt (J.B.); fvaz@fisica.uminho.pt (F.V.)
Lopes, Cláudia;
ORCID
0000-0001-9196-0717
Zugehörigkeit
2 Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693 Ilmenau, Germany; jens.haueisen@tu-ilmenau.de
Fiedler, Patrique;
ORCID
0000-0003-3291-0925
Zugehörigkeit
1 Centro de Física das Universidades do Minho e Porto, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal; marcopsr@gmail.com (M.S.R.); joelborges@fisica.uminho.pt (J.B.); fvaz@fisica.uminho.pt (F.V.)
Rodrigues, Marco Sampaio;
ORCID
0000-0001-7421-6902
Zugehörigkeit
1 Centro de Física das Universidades do Minho e Porto, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal; marcopsr@gmail.com (M.S.R.); joelborges@fisica.uminho.pt (J.B.); fvaz@fisica.uminho.pt (F.V.)
Borges, Joel;
ORCID
0000-0002-0972-9178
Zugehörigkeit
3 Behavioral Imaging and Neural Dynamics Center, University “G. d’Annunzio” of Chieti-Pescara, 66100 Chieti, Italy; maurizio.bertollo@unich.it (M.B.); silvia.comani@unich.it (S.C.)
Bertollo, Maurizio;
ORCID
0000-0003-0633-8937
Zugehörigkeit
5 Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais 1, 1049-001 Lisboa, Portugal; ealves@ctn.tecnico.ulisboa.pt
Alves, Eduardo;
Zugehörigkeit
6 Centro de Ciências e Tecnologias Nucleares, Instituto Superior Técnico, Universidade de Lisboa EN10, 2695-066 Bobadela, Portugal; nunoni@ctn.tecnico.ulisboa.pt
Barradas, Nuno Pessoa;
ORCID
0000-0001-8100-457X
Zugehörigkeit
3 Behavioral Imaging and Neural Dynamics Center, University “G. d’Annunzio” of Chieti-Pescara, 66100 Chieti, Italy; maurizio.bertollo@unich.it (M.B.); silvia.comani@unich.it (S.C.)
Comani, Silvia;
ORCID
0000-0003-3871-2890
Zugehörigkeit
2 Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693 Ilmenau, Germany; jens.haueisen@tu-ilmenau.de
Haueisen, Jens;
ORCID
0000-0001-5506-996X
Zugehörigkeit
1 Centro de Física das Universidades do Minho e Porto, Universidade do Minho, Campus de Gualtar, 4710-057 Braga, Portugal; marcopsr@gmail.com (M.S.R.); joelborges@fisica.uminho.pt (J.B.); fvaz@fisica.uminho.pt (F.V.)
Vaz, Filipe

In a new era for digital health, dry electrodes for biopotential measurement enable the monitoring of essential vital functions outside of specialized healthcare centers. In this paper, a new type of nanostructured titanium-based thin film is proposed, revealing improved biopotential sensing performance and overcoming several of the limitations of conventional gel-based electrodes such as reusability, durability, biocompatibility, and comfort. The thin films were deposited on stainless steel (SS) discs and polyurethane (PU) substrates to be used as dry electrodes, for non-invasive monitoring of body surface biopotentials. Four different Ti–Me (Me = Al, Cu, Ag, or Au) metallic binary systems were prepared by magnetron sputtering. The morphology of the resulting Ti–Me systems was found to be dependent on the chemical composition of the films, specifically on the type and amount of Me. The existence of crystalline intermetallic phases or glassy amorphous structures also revealed a strong influence on the morphological features developed by the different systems. The electrodes were tested in an in-vivo study on 20 volunteers during sports activity, allowing study of the application-specific characteristics of the dry electrodes, based on Ti–Me intermetallic thin films, and evaluation of the impact of the electrode–skin impedance on biopotential sensing. The electrode–skin impedance results support the reusability and the high degree of reliability of the Ti–Me dry electrodes. The Ti–Al films revealed the least performance as biopotential electrodes, while the Ti–Au system provided excellent results very close to the Ag/AgCl reference electrodes.

Zitieren

Zitierform:
Zitierform konnte nicht geladen werden.

Rechte

Nutzung und Vervielfältigung: